[Config] Program=nvgsms Port=COM1 Mode=2400,N,8,1 Description= RemoteSystemName=SMS Modul PhysicalLayer=Modem through RS232 WatchTimeout=6 MoveJobToDoneOrErrorPath=1 WriteToJournalLog=1 JobProcessingLimit=1024 WatchPath=\nvt\nvgsms FileMask=*.sms DonePath=\nvt\nvgsms\done ErrorPath=\nvt\nvgsms\error WatchLogPath=\nvt\log WriteIncomingSMSJobFile=0 IncomingSMSJobPath=\nvt\nvgsms\incomingSMS * Format of execution oft the file is 'start .=* * If WriteIncomingSMSJobFile is 0 it should be a batchfile with it's parameters (start incoming_sms.bat %s %s) .=* * If WriteIncomingSMSJobFile is 1 defined it should be the module nvincomingsms.nve (nve nvincomingsms.nve -s1%s) parameter is the IncomingSMSJobFile .=* CmdLineFormat=start incoming_sms.bat %s %s * To deactivate the old function and use the nvincomingmessage started over jobfile with WDir, then set this value to 0 .=* UseOldIncomingFunctions=0 * If this should work in a redundant system as confirmation, we need to make a request to NVR=* WriteIncomingSMSJobFileToNVR=0 NVRUrl= * Be sure you have a correct value for the PIN. After 3 times restart of the interface and entering a wrong pin, the SIM is locked and you need to .=* * enter the PUK by putting the SIM into a mobilephone. .=* PIN=5028 Number= * Enter the number of the SIM inserted. This is needet to send SMS to itself to check all the functionalities from sending till receiving. .=* OwnNumber= EnableSMSPDUMode=0 InternationalPrefix=00 NationalPrefix=0 MMSURLServer= MMSAPN= MMSIPAddress= MMSPortType= MMSLogin= MMSPWD= MMSContentType=application/vnd.wap.multipart.mixed EnableMMS=1 * Retry functions: When sending not was successful it's possible, that there was just a short failure of the modem. So a retry would make sense .=* RetryCount=5 RetryDelay=120 * RetryOnOtherModule: ( value 0 or 1): retry sending the message on another module if the 'RetryCount' attempts failed with the first module .=* * It only works with many nvgsms module (and many GPRS modems) .=* RetryOnOtherModule=0 * CapitalizeCommands is a function mostly not used. Just in case the modem requires it .=* CapitalizeCommands=0 * TechAlarmNbr is the watchdog-alarm number when in section [ProblemHandling] no alarmnumber is defined .=* TechAlarmNbr=9950 * Time to sleep after a technical alarm in minutes .=* SleepMinAfterAlarm=60 * MaxMsgLength is the length where a message would be cut by the interface. Maximum of this value is 2000 .=* MaxMsgLength=800 FloodProtection=0 IncomingEnable=1 * QualityPollEverySecs is the time between the checks, if the modem has enough signalstrength and can make a registration .=* QualityPollEverySecs=5 * TestSMS is a function that sends periodical an SMS to itself (needs the OwnNumber). If not successful it starts an alarm .=* TestSMSActive=0 SendTestSMSEveryMinutes=30 WaitForTestSMSAfterSendingInSecs=120 WaitAfterSendSecs=0 * Data Scheme coding parameter - not yet implemented .=* DSC=0 DisplaySMSCInfo=1 AutoConnectSetOnSIM=0 VoiceCallDuration=30 * If the warning because of low signalstrength is occuring all the time,=* * even the module works with the low signalstrength, then you can deactivate the warning .=* DeactivateSignalStrengthWarningsInLog=0 * These parameters are for the test-function in the interfacemonitor. So you can handle every interface independant .=* TestDescriptionForMonInterface=Welcome to the function to test the NVGSMS-interface! Please enter a number, you can check if the sending was successful. The message is static. TestMessageForMonInterface=This is a Mobicall testmessage sent by the interface monitor. * ActivateInputThreadHandler in case the SIM sometimes blocks .=* ActivateInputThreadHandler=0 * ActivateExtendedLogs to have more info in log .=* ActivateExtendedLogs=0 IsSecondarySupervisePrimary=0 PrimarySupervisionIntervalInSeconds=30 ProcessErrorOfPrimaryWhenSupervising=0 TestLastNbrForMonInterface=06504198296 [ProblemHandling] * On an error you can set the status of an alarm to 1. On success back to 0. If this function is activated, you can define for input- and output- .=* * alarms different alarms where this should be done .=* * On error and/or on success you can start an alarm. It's actually the watchdogalarm. But these alarms don't start when the connection failed .=* * (then the interface restarts). And then on a failed identification (after restart) -> the alarm starts .=* AlarmDbPath=..\db1 LimitOfSmallErrorsBeforeRestart=10 LimitOfRestartsBeforeStartTechnicalAlarm=2 DoNotMoveJobOnSendingErrorBeforeRestart=0 OnErrorSetStatusOfAlarmTo1= OnInputErrorSetStatusOfAlarm= OnInputErrorStartAlarm= OnOutputErrorSetStatusOfAlarm= OnOutputErrorStartAlarm= OnSuccessSetStatusOfAlarmTo0= OnInputSuccessSetStatusOfAlarm= OnInputSuccessStartAlarm= OnOutputSuccessSetStatusOfAlarm= OnOutputSuccessStartAlarm= OnlyLaunchSuccessAfterError= [Statistics] LastStartup=52088649 FirstInstallation=51ef99d7 LastWDAlr=52087FD4 LastWDSuc=5241999F [Error_Count] InitOut_0=0 InitIn_0=0 Restart_Count=0 [SMSCentralInfo] #For information the current SMS-Central#=* #To change please use a mobile phone an change on SIM-Card#=* #79999000 as example for swisscom gsm network. For all other networks, please check www.airport1.de/handymsc.htm or #=* CurrentSMSCNumber=+43676021 CurrentSMSCNumPlan=145