[Config] DefaultLanguage=DT ShowAlarmPage=1 ShowVoiceMailPage=0 ShowHotelPage=0 [System] NVTPath=D:\nvt\ NVTInstallationDate=8-12-2003 NVTVersion=6.4 SPVersion=Service Pack 4 WinPath=C:\WINNT ComputerName=MOBICALL5 UserName=Administrator AdminPWD= DialogicRelease=SR5.1 DialogicCard=D/300PCI-E1 CPUType=GenuineIntel 2665 MHz RAM=255 MB FreeOnDiskC=9.11 GB FreeOnDiskD=13.04 GB FreeOnDiskE=5.75 GB Comment=IP Port Wago Boxen von EDV auf 10MB/Full eingestellt. Docu= 2ndDialogicCardPresent=0 2ndDialogicCard= WindowsVersion=5.0 DivaServerVersion=Diva Server for Windows 2000/XP/2003 - Version 7.5 (English) 104-304 DivaServerAdapter1= DivaServerAdapter2= [Nvt] NVTPath=D:\nvt\ NVTInstallationDate=2-3-2009 NVTInstallationTime=10:10:47 NVTInstallationLanguage=DT NVTVoxType=WAV NVTVersion=6.82 KeyLinesVoice=20 KeyLinesFax=0 KeyOwner= KeyForRelease=6.8 KeyLicense= Comment= SQLVersion=Nicht installiert SQLInstallationDate= SQLInstallationTime= WebVersion=Nicht installiert WebInstallationDate= WebPath= [Alarm] NVAInstallationDate=2-3-2009 NVAVersion=3.82 FirstAlarmNumber=5000 LastAlarmNumber=9999 AlrSrvDialCode= AlrLaunchNbrs= Appl1=Kontakt Kontroller 2 Appl2=Kontakt Kontroller 3 Appl3=Kontakt Kontroller 4 Appl4= Comment=Box 2 APL Start ALR: 7001 / IP@:172.19.111.242 / IP-Port: 4000|¦Box 3 Biologie Kematen Start ALR: 7033 / IP@: 172.19.111.243 / IP-Port: 4000|¦Box 4 Erstzrechenzentrum Start ALR: 7065 / OP@: 172.19.111.244 / IP-Port: 4000 RecAlrMsgNumber= ComPort1=0 ComPort2=0 ComPort3=0 ComPort4=0 [Lines] Comment= NumberOfLines=4 StartProg1= LineType1= StartProg2= LineType2= StartProg3= LineType3= StartProg4= LineType4= [Addresses] Customer=Mondi Business Paper Austria AG CustomerAddress=Haidmühlstraße 2-4|¦3363 Ulmerfeld-Hausmening PersonInCharge=Hr. Nabecker Johann CustomerPhone=07475/500-2380 CustomerEmail=johann.nabecker@mondibp.com InstallationBy=Schagerl Markus [Additional] MoxaComPorts= RASNumber=07475/500-2394 Comment=nextira|¦nextira|¦Com3 => Typhon USB Modem Docu= Moxa=0 RASComPort=3 RemoteAccess= [Dongle] Comment= KeyLinesVoice=20 KeyLinesFax=0 KeyContacts=96 KeyRelais=24 KeyInterface=2 KeyRegionCode=0 KeyRegionText=Demo Version KeyForRelease=6.8 Solution KeySerial=830E KeySerialDec=33550 KeyTTS=0 RegisteredType= WebProducts=Mobilisierung WebFeatures= WebVisualizerCustom=0 WebVisualizerFix=0 [Interfaces] Interface1=nvipbox 1 Name1=Box1 Biologie Kematen (32/0) ConnectedOn1=172.21.200.243 (Port:502) ConnectionType1=MODBUS/TCP Interface2=nvipbox 2 Name2=Box2 BMA Hausmening (16/0) ConnectedOn2=172.21.200.244 (Port:502) ConnectionType2=MODBUS/TCP Interface3=nvipbox 3 Name3=Box 3 BMA Kematen (16/0) ConnectedOn3=172.21.200.248 (Port:502) ConnectionType3=MODBUS/TCP Interface4=nvipbox 4 Name4=Rechenzentrum Hausmening (32/0) ConnectedOn4=172.21.200.249 (Port:502) ConnectionType4=MODBUS/TCP Interface5=nvipbox 5 Name5=BMA-Hausmening-Relais (0/2) ConnectedOn5=172.21.200.244 (Port:502) ConnectionType5=MODBUS/TCP Interface6=nvipbox 6 Name6=BMA-KEMATEN (0/2) ConnectedOn6=172.21.200.248 (Port:502) ConnectionType6=MODBUS/TCP Interface7=nvgsms Name7= ConnectedOn7=COM2 (19200,N,8,1) ConnectionType7=Comport Interface8=nvitcpipscan Name8=1 -s1nvihilis -s216710 ConnectedOn8= ConnectionType8= Interface9=nvitcpipscan Name9=1 -s1nvihilis -s216711 ConnectedOn9= ConnectionType9= Interface10=nvitcpipscan Name10=1 -s1nvihilis -s216712 ConnectedOn10= ConnectionType10= Interface11=nvitcpipscan Name11=1 -s1nvihilis -s216713 ConnectedOn11= ConnectionType11= Interface12=nvitcpipscan Name12=1 -s1nvisps -s216714 ConnectedOn12= ConnectionType12= Interface13=nvitcpipscan Name13=1 -s1nvisps -s216715 ConnectedOn13= ConnectionType13= Interface14=ComPortServer nvcsrvr Name14=Tgˆw gˆw¸Œ ConnectedOn14= () ConnectionType14=Comport Interface15=ComPortServer nvcsrvr Name15=Tgˆw gˆw¸Œ ConnectedOn15= () ConnectionType15=Comport