Watchdog M3581 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Blockdiagram ÍÍÍÍÍÍÍÍÍÍÍÍ ÚÄÄÄÄÄÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ ³ ³ ³ ³PABX ³ ³ ³ ³ L1 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´Line 1 ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ L2 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´Line 2 ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ T2 ³ ÚÄÄÄÄÄÄÄÄ¿ ³ ³ ÀÄÄÄÂÄÄÄÄÄÄÄÙ ³ 2MB- ³ ³ ³ ³ ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´2MB-SW (Option) ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄ´ Switch ³ ³ ³ ÚÄÄÄÄÄÄÄÄÄÄÄÄ´ Interf.³ ³ ³ ³ ³(Option)³ ³ WATCHDOG BOX ³ ÚÄÄÄÄÁÄÄÄÄÄÄÄ¿ ÀÄÄÄÄÄÄÄÄÙ ³ ³ ³ Alarm ³ ³ ³ ³ ³ ÚÄÄÄÄÄÄÄÄÄÄ¿ ³ ³ ³ Server ³ ³ ³ ³ ³ ³ ³ ³ Alarm ÃÄÄÄÄÄÄÄÄÄÄÄÄÄ´Disp ³ ³ ³ ³ ³ ³ ³ ³ ETH ³ ³ Display ³ ³ ³ ÀÄÄÄÄÂÄÄÄÄÄÄÄÙ ³ ³ ³ ³ ³ ³ Unit ³ ³ ³ ³ IP ³ ³ ³ ³ ÄÄÄÂÄÄÄÄÁÄÄÄÄÄÄÄÄÄ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ Wago ÀÄÄÄÄÄÄÄÄÄÄÙ ³ ³ ÚÄÁÄÂÄÄÄÂÄÄÄÂÄÄÄ¿ ³ ³ ³ ³ ³ ³ ÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´Wago ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ZLT-Alarm ³ ³ ³ ³ ³ ³ ³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ZLT-AL ³ ³ ³ ³ ³ ³ ³ 48V ³ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ³ + - ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÂÄÂÄÄÄÄÄÄÄÄÄÙ ³ ³ ³ ³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³ Power Supply 48V ³ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Funktion: ÍÍÍÍÍÍÍÍÍ The watchdog box consists of the following functions: 3 type of watchdog alarm. Type 1 Alarm: Configuration for type 1 alarm is the default configuration (REG 000 bit 0 = 1). Type 1 alarm use line 1 The Alarm Server (AS) calls every 30 minutes (REG 002) the extension number of line 1. After the number of rings (REG 003) the WD-Box answers the call and goes onhook after 7 sec. If there is no call arrived within the last 30 minutes (REG 002) the WD-Box start a timeout of REG 002/2. After one additional timeout the WD-Box start an outgoing alarm (Alarm = 1). The alarm will be stopped at next call to line 1. Reg 000 Bit 3 = 1 Watchdog box make a callback to the alarm server. Alarm input on the alarn server should be prorammed as type LINE TEST CALLBACK. Details for configuration for NV alarm server see configuration of CAVEO BOX. Reg 010: timer for hotline call. Units sec. This timer defines the time how long the WD box wait after the call and how long the WD box goes offhook. Type 2 Alarm: Type 2 alarm use line 2. Type 2 alarm is enabled in REG 000 bit 1 = 1. Type 2 alarm switches the contact "WAGO" inside the WD-Box to on. The alarm is started every (REG 005) minutes. The contact "WAGO" is on for the timer (REG 006). This contact should start via the Wago Contact Box an alarm inside the AS. This alarm should call the extension number line 2. When the call is received within the timer (REG 006) then the alarm is answered correct. If there is no call within the timer (REG 006), the WD-Box switch off the contact "WAGO" for the timer (REG 006) and close the contact "WAGO" again. After 3 tries without a call on line 2 the WD-Box start an outgoing alarm. Type 3 Alarm: Type 3 alarm uses line 2 as hotline (configuration see Hotline Config). Type 3 alarm is enabled in REG 000 bit 2 = 1. The WD-Box starts every timer (REG 007) a Hotline call to the AS. Inside the AS the hotline call start an alarm that should call the extension of line 2. This alarm should be started delayed by 10 sec in the alarm configuration of the AS. The WD-Box unit hangs up the line 2 after 7sec and awaits now a call within the timer (REG 008). If there is no incoming call within the timer (REG 008) the WD-Box start after a waiting time of timer (REG 008) the hotline call again. After 3 tries the WD-Box start an outgoing alarm. On power on the WD-Box test the line 1 and line 2 if there is a type of alarm enabled that is using this line. Outgoing Alarm: Each type of alarm set a flag in case of alarm. If one of that fag are set an outgoing alarm is started. The external display goes active, the LED red is switched on and also the buzzer goes on. The contact ZLT-Alarm is switched on. This contact can be used to signal a external device. Bit 0 of REG 001 can invert the funktion ON/OFF of the relais contact of ZLT-Alarm. On the Alarm Display Unit the buzzer can be reset by pressing the green key. The outgoing alarm is active as long as there is at least on alarm flag active. If all alarm flags are off the outgoing alarm goes into the inactive state. When timer (REG 004) is set to value other then 0 the outgoing alarm will be reset after the timer (REG 004) for 1 sec and start again. In this case the buzzer will also go on again. HOTLINE Config: ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ A4400 Categories > Phone Facilities Categories +-Consult/Modify: Phone Facilities Categories--------------------+ | | | Routing Mode At Off Hook + Direct Routing | Specific Telephone Services > Routing Table +-Consult/Modify: Routing Table----------------------------------+ | | | Node Number (reserved) : 101 | | Instance (reserved) : 1 | | Routing No. : 1 | | | | Call Number : 5201020 | | | +----------------------------------------------------------------+ Users +-Consult/Modify: Users------------------------------------------+ | | | Directory Number : xxxxx | | Routing Table : 1 | CONNECTOR --------- WAGO: A oÄÄÄÄÄÄÄ¿ W oÄÄÄÄÄÄ\ \ R oÄÄÄÄÄÄÄÙ ZLT-AL: A oÄÄÄÄÄÄÄ¿ W oÄÄÄÄÄÄ\ \ R oÄÄÄÄÄÄÄÙ Displ: 1 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ 2 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ +UB (+48V) 3 === R 4 === A 5 === W 6 === nc 7 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ 8 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ -UB (-48V) 2MB-SW: 1 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ 2 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ +UB (+48V) 3 === R 4 === A 5 === W 6 === nc 7 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ 8 ===ÄÄÄÄÄÄÄÄÄÄÄÄÄ -UB (-48V) Line 1: Line 2: 1 === 2 === 3 ===ÄÄÄÄÄÄÄ a 4 ===ÄÄÄÄÄÄÄ b 5 === 6 === Watchdog MONITOR ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Type for display prompt. EEPROM_MON V1.0 > Commands: X Reset and read new values from eeprom. A Start an alarn output C Clear the alarm output 1 Start alarm type 1 2 Start alarm type 2 3 Start alatm type 3 E(nnn) Edit register "nnn" from eeprom. If no value "nnn" edit register 0. ... next register "-" ... prior register "value" ... new value for register "." ... exit to monitor CONNECTIONCABEL for MONITOR ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ RJ45 9 pin PC ÚÄÄÄÄÄÄÄÄ 2 3 ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ 6 ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 3 5 ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 5 CONFIGURATION of PC-COM-PORT ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ 9600 bit/s 1 start-bit non parity 1 stop-bit CONFIGURATION of Watchdog _________________________ REG. DATA __________ 000 Bit 0 = 0 Type 1 Alarm disable (normal call from sever) Bit 0 = 1 Type 1 Alarm enable Bit 1 = 0 Type 2 Alarm disable (make contact and wait for call) Bit 1 = 1 Type 2 Alarm enable Bit 2 = 0 Type 3 Alarm disable (hotline call to server and wait for call from server) Bit 2 = 1 Type 3 Alarm enable Bit 3 = 0 Type 1 alarm without callback = 1 Type 1 alarm with callback. After call in WD-Box answers the call, hookon the line for 7 sec and hookof the line for 7 sec. Default = 9 001 nnn = Bit 0 = 0 ZLT-Relais on no alarm off Bit 0 = 1 ZLT-Relais on no alarm on Default= 1 002 nnn = Timer for Type1 Alarm in minutes Default = 30 003 nnn = Number of rings befor offhook Default = 2 004 nnn = Alarm out timer: Repeat the Alarmout after minutes If 0 no repeat Default = 60 005 nnn = Type 2 alarm (Wago) timout for test timer unit 1 minutes Default = 255 006 nnn = Type 2 alarm (Wago) timout for waiting for call after contact is on timer unit 1 minutes Default = 255 007 nnn = Type 3 alarm (Hotline Call) timeout for test timer unit 1 minutes Default = 255 008 nnn = Type 3 alarm (Hotline Call) timeout for waiting for call after hotline call (7 sec) Alarm from Server should be delayed for 7 sec minimum. timer unit 1 minutes Default = 255 009 nnn = timer used for OFFHOOk after a call Units sec default = 9 010 nnn = timer used for setting the HOTLINE CALL Units sec default = 9 011 nnn = config Parameter (99 = 'c'). if this parameter is at startup time not 99 ('c') then the default configuration is loaded. History: Version 1.0 Basic. Version 2.0 2009-01-26 EEpromstruct byte 1 for changing the polarity of the relais ZLT Implement the callback for type 1 alarm on line 2. Version 3.0 2009-02-11 Reg 10 for programming the HOTLINE CALL. Monitor commands A and C implemented Default init of REG 000 changed to 9 Version 4.0 2009-02-16 REG 9 for programming the OFFHOOK time Monitor commands 1, 2, 3 added Default init REG 9 and REG 10 value 9 (sec) Monitor Output: =============== (334943) ----->Type 3 Alarm > RLD-mess:4 (334943) ----->Type 3 Alarm > Ring (334948) ----->Type 3 Alarm > RLD-mess:4 (334948) ----->Type 3 Alarm > Ring (334948) ----->Type 3 Alarm > Answer (334955) ----->Type 3 Alarm > free line2 (334955) ----->Type 3 Alarm > State 0 (334959) Alarm_OUT State 0 no alarm (335079) Alarm_OUT State 0 no alarm (335199) Alarm_OUT State 0 no alarm (335319) Alarm_OUT State 0 no alarm (335439) Alarm_OUT State 0 no alarm (335520) ----->Type 3 Alarm > waiting line2 seizure (335520) ----->Type 3 Alarm > seizure line2 (335520) ----->Type 3 Alarm > Start HOTLINE Call (335527) ----->Type 3 Alarm > Stop hotline Call (335527) ----->Type 3 Alarm > RLD-mess:1 (335543) ----->Type 3 Alarm > RLD-mess:4 (335543) ----->Type 3 Alarm > Ring (335548) ----->Type 3 Alarm > RLD-mess:4 (335548) ----->Type 3 Alarm > Ring (335548) ----->Type 3 Alarm > Answer (335555) ----->Type 3 Alarm > free line2 (335555) ----->Type 3 Alarm > State 0 (335559) Alarm_OUT State 0 no alarm (335679) Alarm_OUT State 0 no alarm (335799) Alarm_OUT State 0 no alarm (335919) Alarm_OUT State 0 no alarm (336039) Alarm_OUT State 0 no alarm (336120) ----->Type 3 Alarm > waiting line2 seizure (336120) ----->Type 3 Alarm > seizure line2 (336120) ----->Type 3 Alarm > Start HOTLINE Call (336127) ----->Type 3 Alarm > Stop hotline Call (336159) Alarm_OUT State 0 no alarm (336180) ----->Type 3 Alarm > Alarm counter:3 (336180) ----->Type 3 Alarm > free line2 (336180) ----->Type 3 Alarm > State 0 (336240) ----->Type 3 Alarm > waiting line2 seizure (336240) ----->Type 3 Alarm > seizure line2 (336240) ----->Type 3 Alarm > Start HOTLINE Call (336247) ----->Type 3 Alarm > Stop hotline Call (336279) Alarm_OUT State 0 no alarm (336300) ----->Type 3 Alarm > Alarm counter:2 (336300) ----->Type 3 Alarm > free line2 (336300) ----->Type 3 Alarm > State 0 (336360) ----->Type 3 Alarm > waiting line2 seizure (336360) ----->Type 3 Alarm > seizure line2 (336360) ----->Type 3 Alarm > Start HOTLINE Call (336367) ----->Type 3 Alarm > Stop hotline Call (336399) Alarm_OUT State 0 no alarm (336420) ----->Type 3 Alarm > Alarm counter:1 (336420) ----->Type 3 Alarm > A L A R M (336420) ----->Type 3 Alarm > free line2 (336420) ----->Type 3 Alarm > State 0 (336420) Alarm_OUT State 1 A L A R M = 4 (336540) Alarm_OUT State 1 A L A R M = 4 (336660) Alarm_OUT State 1 A L A R M = 4 (336720) ----->Type 3 Alarm > waiting line2 seizure (336720) ----->Type 3 Alarm > seizure line2 (336720) ----->Type 3 Alarm > Start HOTLINE Call (336727) ----->Type 3 Alarm > Stop hotline Call (336780) Alarm_OUT State 1 A L A R M = 4 (336780) ----->Type 3 Alarm > Alarm counter:0 (336780) ----->Type 3 Alarm > A L A R M (336780) ----->Type 3 Alarm > free line2 (336780) ----->Type 3 Alarm > State 0 (336900) Alarm_OUT State 1 A L A R M = 4 (337020) Alarm_OUT State 1 A L A R M = 4 (337020) Alarm_OUT reactivate ALARM OUTPUT !!! (337022) Alarm_OUT State 1 A L A R M = 4 (337080) ----->Type 3 Alarm > waiting line2 seizure (337080) ----->Type 3 Alarm > seizure line2 (337080) ----->Type 3 Alarm > Start HOTLINE Call (337087) ----->Type 3 Alarm > Stop hotline Call (337087) ----->Type 3 Alarm > RLD-mess:1 (337103) ----->Type 3 Alarm > RLD-mess:4 (337103) ----->Type 3 Alarm > Ring (337108) ----->Type 3 Alarm > RLD-mess:4 (337108) ----->Type 3 Alarm > Ring (337108) ----->Type 3 Alarm > Answer (337115) ----->Type 3 Alarm > free line2 (337115) ----->Type 3 Alarm > State 0 (337115) Alarm_OUT State 0 no alarm (337235) Alarm_OUT State 0 no alarm (337355) Alarm_OUT State 0 no alarm Default config E 000 001 = 001 001 = 002 030 = 003 002 = 004 060 = 005 255 = 006 255 = 007 255 = 008 255 = 009 255 = 010 255 = 011 099 = 012 255 = 013 255 = 014 255 = ************************************************************************